Live drug, device & food recall data from the FDA (openFDA enforcement) — food spanning dietary supplements, cosmetics & animal food — mapped to the GxP quality domains SPEQ assesses, so you can see where control breaks down across every regulated industry.
1,000
Total recalls
217
Class I (most serious)
167
Drug
515
Device
318
Food / supplement / cosmetic
Last 12 months · latest report 2026-07-22 · source: openFDA enforcement
RECALLS BY CLASSIFICATION · MONTHLY
RECALL REASONS BY QUALITY DOMAIN
Domain mapping is a SPEQ interpretation of the FDA recall reason, not an official FDA classification.
27 matching recalls
| Date | Class | Firm | Reason | Quality domain |
|---|---|---|---|---|
| 2026-07-15 | Class II | Medtronic MiniMed, Inc.Z-2698-2026 | A software anomaly can occur when the pump is paired with the Instinct sensor. Under certain circumstances, the pump unexpectedly stops delivering insulin and displays two error messages back-to-back: Pump Error 53 followed immediately by Pump Error 23. Insulin delivery will stop which may lead to delayed therapy and an increased risk of hyperglycemia or diabetic ketoacidosis (DKA). | Data Integrity |
| 2026-07-15 | Class II | CMR SURGICAL LIMITEDZ-2717-2026 | Secure Boot was mistakenly not enabled at manufacturing time, which presents a potential cybersecurity risk. | Data Integrity |
| 2026-07-01 | Class II | IPG Medical CorporationZ-2554-2026 | Software anomaly that causes a false display of error code 5018. | Data Integrity |
| 2026-06-24 | Class I | Abiomed, Inc.Z-2360-2026 | Potential software error in the Automated Impella Controller ("AIC" ) when used in conjunction with left ventricular Impella devices. | Data Integrity |
| 2026-06-24 | Class II | Medtronic Navigation, Inc.-BoxboroughZ-2451-2026 | Potential for image artifacts caused by an anomaly in the O-arm O2 Imaging System s detector panel firmware. | Data Integrity |
| 2026-06-24 | Class II | Beta Bionics, Inc.Z-2513-2026 | The reason for the recall is: it was found in version 3.3.6 of the iLet ACE Pump firmware and all previous releases that a screen unlock failure could occur when the user successfully slides the unlock slider on the Lock Screen, no screen transition occurs, and the user remains on the Lock Screen. Because the user cannot exit the Lock Screen, the user is unable to perform a cartridge change or meal announcement. If this occurs and therapy is in progress, therapy will continue normally until the insulin cartridge is depleted. The user will be unable to perform a cartridge change or a meal announcement and will be stuck on the screen until the battery fully drains. This can lead to hyperglycemia. | Data Integrity |
| 2026-06-17 | Class II | Abbott MedicalZ-2405-2026 | Software malfunction may occur during pacing capture threshold test of pacemaker resulting in programmer not successfully communicating the command to terminate the test. | Data Integrity |
| 2026-06-17 | Class II | Micromed S.p.A.Z-2353-2026 | Natus has become aware of two complaints related to the SD LTM 64 PLUS where the EEG traces acquired from two or four different amplifiers used in a multiple amplifier configuration (128 or 256 channels) running firmware version 2022.02 were displayed with a shift of 1 second between the 64channels blocks. In rare circumstances, a fixed 1-second temporal delay may appear between two 64-channel modules with firmware 2021.02, 2022.01 or 2022.02 in a multi-module SEEG configuration, potentially leading to misinterpretation of results. | Data Integrity |
| 2026-06-10 | Class II | GE Medical Systems China Co., Ltd.Z-2306-2026 | Software in development inadvertently made available for customer use. Use of this software version can result in clinical information being associated with the incorrect patient. This could impact clinical decision-making. | Data Integrity |
| 2026-06-10 | Class I | Fresenius Kabi USA, LLCZ-2223-2026 | Potential software anomaly that can cause the pump to report a false battery-health value (typically 69%) and trigger a battery-depletion alarm that will shut down the pump unless it is reconnected to AC mains power. | Data Integrity |
| 2026-05-20 | Class II | Dexcom, Inc.Z-2165-2026 | A software defect in which a low-priority file I/O check blocks the higher-priority thread responsible for processing estimated glucose values (EGVs) and trend arrows. When the app is running in the background, EGV notifications may queue up and then "replay" sequentially when the user brings the app to the foreground, causing the Glucose Compass to flicker through previous EGVs. In more severe instances, the app may perceive signal loss and deploy signal loss mitigations. This delay in EGV and alert processing creates a risk that users may miss detection of a hypoglycemic or hyperglycemic event, or make treatment decisions based on outdated glucose information. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2150-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2152-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2154-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2149-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2155-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | Dexcom, Inc.Z-2164-2026 | A software defect in which a low-priority file I/O check blocks the higher-priority thread responsible for processing estimated glucose values (EGVs) and trend arrows. When the app is running in the background, EGV notifications may queue up and then "replay" sequentially when the user brings the app to the foreground, causing the Glucose Compass to flicker through previous EGVs. In more severe instances, the app may perceive signal loss and deploy signal loss mitigations. This delay in EGV and alert processing creates a risk that users may miss detection of a hypoglycemic or hyperglycemic event, or make treatment decisions based on outdated glucose information. | Data Integrity |
| 2026-05-20 | Class II | Dexcom, Inc.Z-2163-2026 | A software defect in which a low-priority file I/O check blocks the higher-priority thread responsible for processing estimated glucose values (EGVs) and trend arrows. When the app is running in the background, EGV notifications may queue up and then "replay" sequentially when the user brings the app to the foreground, causing the Glucose Compass to flicker through previous EGVs. In more severe instances, the app may perceive signal loss and deploy signal loss mitigations. This delay in EGV and alert processing creates a risk that users may miss detection of a hypoglycemic or hyperglycemic event, or make treatment decisions based on outdated glucose information. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2153-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | GE Medical Systems, LLCZ-2151-2026 | GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems. | Data Integrity |
| 2026-05-20 | Class II | Technological Medical Advancements LLCZ-2162-2026 | Software update is needed for laser systems, for topical infrared heating to provide temporary relief of minor muscle and joint pain, spasms, stiffness associated with minor arthritis, and to temporarily increase local blood circulation, operating at a maximum average power output of 70W, which is beyond the FDA cleared 60W. | Data Integrity |
| 2026-05-06 | Class II | Beta Bionics, Inc.Z-1996-2026 | insulin pump software versions 1.4.2, and 1.4.3 issue with Dexcom Continuous Glucose Monitoring (CGM) G7 sensor may result in delayed CGM reading then switch to non-CGM dosing, leading to only basal/requested meal doses provided, no correction doses/insulin reductions/suspensions for high/low glucose unless blood glucose entered for sensor life or replacement. Potential health risks to users include severe hyperglycemia with and without DKA and severe hypoglycemia. | Data Integrity |
| 2026-04-22 | Class II | Gentuity, LLCZ-1823-2026 | The potential for repeated frames during HF-OCT pullback when using the Gentuity HF-OCT Console (software version 21.11 to 23.3.13) with the Vis-Rx and Vis-Rx Prime catheters. This correction is intended to ensure that users are fully informed of how to recognize, avoid, and mitigate this condition to maintain accurate longitudinal (length) measurements during OCT imaging. | Data Integrity |
| 2026-04-08 | Class II | Reflexion Medical, Inc.Z-1656-2026 | Due to a radiotherapy medical system software defect, when performing angular roll corrections followed by a repeat localization, the roll corrections applied in the initial localization scan are not carried through to treatment delivery leading to the treatment plan dose being delivered to the incorrect location, potentially a displacement of 5mm or higher, with a 10% to 20% underdose. | Data Integrity |
| 2026-04-01 | Class II | Medtronic MiniMed, Inc.Z-1635-2026 | Three software defects (Pump Error 53, BG check, and Critical Pump Error (Open Book Image)) that occurred as a result of software updates (versions 6.60, 6.61, and 6.62), which could result in a risk of hypoglycemia or hyperglycemia due to inaccuracies in insulin delivery (either under-delivery, over-delivery, or cessation of delivery). | Data Integrity |
Page 1 of 2