FDA PRODUCT CODE · CLASS I

NXF — Gas, Laser Generating

Special laser gas mixtures used as a lasing medium

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class I
REGULATION
21 CFR 878.4810
MEDICAL SPECIALTY
General, Plastic Surgery
REVIEW PANEL
SU
— Implant— Life-sustaining— GMP-exempt— Third-party review eligible
0
510(K)/PMA CLEARANCES
0
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K) Exempt

SPEQ READINGNo premarket notification is required for a device in this code, within the limitations of exemption. Exempt from premarket review is NOT exempt from regulation: registration, listing, labelling, adverse-event reporting and — unless the code is also GMP exempt — 21 CFR Part 820 all still apply.

DEVICE CLASS

Class I (low to moderate risk): general controls

SPEQ READINGGeneral controls carry the whole regulatory burden here — registration, listing, labelling, adverse-event reporting and prohibitions against adulteration and misbranding.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

Other product codes under 21 CFR 878.4810

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

GEXPowered Laser Surgical InstrumentLNKLaser For Gastro-Urology UseNUVMassager, Vacuum, Light Induced HeatingNVKLaser, Dental, Soft TissueOELLaser, Benign Prostatic HyperplasiaOHSLight Based Over The Counter Wrinkle ReductionOHTLight Based Over-The-Counter Hair RemovalOLPOver-The-Counter Powered Light Based Laser For AcneONEPowered Light Based Non-Laser Surgical InstrumentONFPowered Light Based Non-Laser Surgical Instrument With Thermal EffectONGPowered Laser Surgical Instrument With MicrobeamFractional OutputONONeurosurgical Laser With Mr ThermographyORKLaser Assisted LipolysisOYWLaser, Cellulite AppearancePDZLasers For Temporary Increase Of Clear Nail In Patients With OnychomycosisPKOTransparent Patch For Use In Treatment Of TattoosQCYLaser Absorbing ParticlesQHFEnergy Based Device For Treatment Of Tattoos

21 CFR 878.4810 — Laser surgical instrument for use in general and plastic surgery and in dermatology

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification.

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.

(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

(b) Classification.

(1) Class II.

(2) Class I for special laser gas mixtures used as a lasing medium for this class of lasers. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 878.9. [53 FR 23872, June 24, 1988, as amended at 61 FR 1123, Jan. 16, 1996; 66 FR 38803, July 25, 2001]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 878.4810 on eCFR →

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →