FDA PRODUCT CODE · CLASS II

PPB — Foley Catheter Kit (Excludes Hiv Testing)

This product code has been established in accordance with the may 20, 1997, guidance entitled, convenience kits interim regulatory guidance, found at http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm080217.pdf. This type of convenience kit, as listed in the guidance above, is under enforcement discretion, and does not require a premarket notification (510(k)) to market if it meets all criteria in the guidance.

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 876.5130
MEDICAL SPECIALTY
Gastroenterology, Urology
REVIEW PANEL
GU
— Implant— Life-sustaining— GMP-exempt— Third-party review eligible
0
510(K)/PMA CLEARANCES
3
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

FDA publishes no definition for this value in the device classification field reference, so SPEQ does not interpret it.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

Other product codes under 21 CFR 876.5130

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

EYAStylet, UreteralEYBCatheter, Ureteral, Gastro-UrologyEYCCatheter, Upper Urinary TractEYIAdaptor, Ureteral CatheterEYJHolder, Ureteral CatheterEYKConnector, Ureteral CatheterEZBStylet For Catheter, Gastro-UrologyEZCCatheter, CoudeEZDCatheter, StraightEZLCatheter, Retention Type, BalloonFCMTray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)FGFCatheter, Ureteral Disposable (X-Ray)FGHCatheter, Double Lumen Female UrethrographicFGICatheter, Urethrographic, MaleGBLCatheter, Ureteral, General & Plastic SurgeryGBMCatheter, UrethralKNYAccessories, Catheter, G-UKODCatheter, UrologicalLJHSystem, Irrigation, UrologicalMJCCatheter, Urological (Antimicrobial) And AccessoriesNWOKit, Catheter, Urinary (Exludes Hiv Testing)OHRCatheter Care TrayPPABladder Irrigation KitPPCMale External Catheterization Kit (Excludes Hiv Testing)

21 CFR 876.5130 — Urological catheter and accessories

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudé catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).

(b) Classification.

(1) Class II (performance standards).

(2) Class I for the ureteral stylet (guidewire), stylet for gastrourological catheter, ureteral catheter adapter, ureteral catheter connector, and ureteral catheter holder. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. [48 FR 53023, Nov. 23, 1983, as amended at 61 FR 1122, Jan. 16, 1996; 66 FR 38801, July 25, 2001]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 876.5130 on eCFR →

Recent recalls

MEDLINE INDUSTRIES, LP - NorthfieldOpen, Classified · 2024-12-30

Custom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.

MEDLINE INDUSTRIES, LP - NorthfieldOpen, Classified · 2024-10-23

It has been determined that certain Convenience kits that were packaged in breather pouch lot 323080002 may result in the potential of using non-sterile product if the vendor seal of the pouch is opened/unsealed.

MEDLINE INDUSTRIES, LP - NorthfieldOpen, Classified · 2023-02-06

Sterile blades within sterile kits have the potential for the blade to puncture the outer foil layer of the sterile packaging.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →