FDA PRODUCT CODE · CLASS II

LHN — System, Radiation Therapy, Charged-Particle, Medical

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 892.5050
MEDICAL SPECIALTY
Radiology
REVIEW PANEL
RA
— Implant— Life-sustaining— GMP-exempt— Third-party review eligible
7
510(K)/PMA CLEARANCES
510k: 7
18
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

Other product codes under 21 CFR 892.5050

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 892.5050 — Medical charged-particle radiation therapy system

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.

(b) Classification. Class II. When intended for use as a quality control system, the film dosimetry system (film scanning system) included as an accessory to the device described in paragraph (a) of this section, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9. [53 FR 1567, Jan. 20, 1988, as amended at 64 FR 1125, Jan. 8, 1999]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 892.5050 on eCFR →

Recent clearances

K260597ProNova Solutions · 510k2026-09-23
K260174Hitachi High-Tech Corp. · 510k2026-06-11
K252815Varian Medical Systems, Inc. · 510k2026-04-23
K253406Mevion Medical Systems, Inc. · 510k2026-03-25
K250986Mevion Medical Systems, Inc. · 510k2025-09-12
K243900Empnia, Inc. · 510k2025-06-27
K242418P-Cure, Ltd. · 510k2025-05-12

Recent recalls

Ion Beam Applications S.A.Open, Classified · 2023-11-14

The patient positioning system can perform motions in unexpected directions, creating the potential for crushing of the patient between the patient positioning devices.

Mevion Medical Systems, Inc.Terminated · 2016-02-08

The treatment table positioning belt can slip gear positions, resulting in deviation of patient setup and treatment positions from the time of slippage until the discovery of slippage and the halting of treatment.

Ion Beam Applications S.A.Terminated · 2014-12-19

Two issues were identified: 1. In the release of adaPT insight v1.3.2., the kV/kV Single Source acquisition workflow was linked to a wrong geometrical calibration file, resulting in an alignment offset for this specific mode of acquisition. 2. A gantry collision incident required

Mevion Medical Systems, Inc.Terminated · 2014-12-12

Software defect that causes an incorrect dose compensation function to be applied to the internal dose ionization chamber when either pressure or temperature sensor malfunction. This could result in an incorrect dose delivery of no more than 5%.

Intraop Medical CorporationTerminated · 2008-10-03

Docking screw/nut failure, which may result in a treatment head dropping, potentially impacting the patient.

Mizuho Orthopedic Systems IncTerminated · 2007-12-13

Failure to anchor; due to a failure in the locking mechanism, the product may not anchor properly.

Mizuho Orthopedic Systems IncTerminated · 2007-12-13

Failure to anchor; due to a failure in the locking mechanism, the product may not anchor properly.

Mevion Medical Systems, Inc.Terminated

Treatment beam information disappears on Treatment Console screen while beam delivery continues potential for harm to a patient could occur

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →