FDA PRODUCT CODE · CLASS II

FZP — Clip, Implantable

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 878.4300
MEDICAL SPECIALTY
General, Plastic Surgery
REVIEW PANEL
SU
✓ Implant— Life-sustaining— GMP-exempt— Third-party review eligible
7
510(K)/PMA CLEARANCES
510k: 7
21
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is implantable

SPEQ READINGImplant status raises the evidentiary bar on biocompatibility and on traceability from finished device back to material lot.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

Other product codes under 21 CFR 878.4300

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 878.4300 — Implantable clip

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. An implantable clip is a clip-like device intended to connect internal tissues to aid healing. It is not absorbable.

(b) Classification. Class II.

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 878.4300 on eCFR →

Recent clearances

K260677Vcd Medical S.R.L. · 510k2026-09-17
K254231Taiwan Surgical Corporation · 510k2026-07-20
K253781Taiwan Surgical Corporation · 510k2025-12-22
K253903Taiwan Surgical Corporation · 510k2025-12-22
K250643Hangzhou Kangji Medical Instrument Co., Ltd. · 510k2025-11-20
K251054Teleflex Medical · 510k2025-07-03
K242541Synovis Micro Companies Alliance A Subsidiary of Baxter Int · 510k2025-01-15

Recent recalls

Teleflex MedicalTerminated · 2016-02-25

The clip in the applier may be missing a boss. A boss is the part of the clip that is used to hold the clip within the applier jaws prior to application.

Teleflex MedicalTerminated · 2014-12-17

The manufacturing dates and expiration dates were transposed on the Tyvek label.

Teleflex MedicalTerminated · 2012-10-18

Product is being recalled due to the possibility that the tray may contain pinholes, compromising product sterility.

Telefelx MedicalTerminated · 2008-09-16

A hole in the sterile unit blister pack was detected that would compromise sterility.

Telefelx MedicalTerminated · 2008-09-16

A hole in the sterile unit blister pack was detected that would compromise sterility.

Telefelx MedicalTerminated · 2008-09-16

A hole in the sterile unit blister pack was detected that would compromise sterility.

Telefelx MedicalTerminated · 2008-09-16

A hole in the sterile unit blister pack was detected that would compromise sterility.

Telefelx MedicalTerminated · 2008-09-16

A hole in the sterile unit blister pack was detected that would compromise sterility.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →