FDA PRODUCT CODE · CLASS II

FMI — Needle, Hypodermic, Single Lumen

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 880.5570
MEDICAL SPECIALTY
General Hospital
REVIEW PANEL
HO
— Implant— Life-sustaining— GMP-exempt✓ Third-party review eligible
24
510(K)/PMA CLEARANCES
510k: 24
141
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is not eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGIndividual malfunction reporting under 21 CFR Part 803 applies. The complaint-handling system has to produce a decision per event, not per period.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is a candidate for a third party review program

SPEQ READINGAn Accredited Person may conduct the 510(k) review instead of FDA. FDA still makes the clearance decision — third-party review changes who reviews, never who decides.

Other product codes under 21 CFR 880.5570

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 880.5570 — Hypodermic single lumen needle

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.

(b) Classification. Class II (performance standards).

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 880.5570 on eCFR →

Recent clearances

K261266PENTAMASTER MEDIQ SDN BHD · 510k2026-09-17
K261719Promisemed Hangzhou Meditech Co., Ltd. · 510k2026-08-25
K262427Hh Global Technology, Inc. · 510k2026-08-10
K260933Hangzhou Qiantang Longyue Biotechnology Co., Ltd. · 510k2026-08-07
K261829CMT Health PTE., Ltd. · 510k2026-07-29
K260739CMT Health PTE., Ltd. · 510k2026-07-15
K260855CMT Health PTE., Ltd. · 510k2026-06-10
K254273Promisemed Hangzhou Meditech Co., Ltd. · 510k2026-04-16

Recent recalls

Greiner Bio-One GmbHOpen, Classified · 2025-01-03

The VACUETTE SAFELINK Holder with male luer lock may leak blood due to the protective rubber sleeve bunching up and not retracting when using the device.

Becton Dickinson & CompanyTerminated · 2019-10-31

BD PAS received customer complaints indicating the absence of the bevel on the non-patient needle end of the product, causing blood leakage.

Myco Medical Supplies IncTerminated · 2015-12-17

Particulates: Complaints of rubber coring from the closure of injection vials.

Smiths Medical ASD, Inc.Completed · 2014-12-30

Needle is not captured in the needle safety sheath in specific lots.

Smiths Medical ASD, Inc.Completed · 2014-12-30

Needle is not captured in the needle safety sheath in specific lots.

Smiths Medical ASD, Inc.Completed · 2014-12-30

Needle is not captured in the needle safety sheath in specific lots.

Greiner Bio-One North America, Inc.Terminated · 2013-02-15

The VACUETTE Safety Blood Collection Set + Luer Adapter may display leaking (small droplets) during use due to a crack on the luer connector piece.

Becton Dickinson & CompanyTerminated · 2012-02-13

Becton Dickinson has identified clogged needles.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →