FDA PRODUCT CODE · CLASS II

FLL — Continuous Measurement Thermometer

A continuous measurement thermometer is a clinical electronic thermometer indicated to measure the body or skin temperature of a person continuously or in specified intervals. Under this regulation, this product code represents non-exempt devices. For more information, see 90 FR 25889, available at https://www.govinfo.gov/content/pkg/FR-2025-06-18/pdf/2025-11207.pdf.

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 880.2910
MEDICAL SPECIALTY
General Hospital
REVIEW PANEL
HO
— Implant— Life-sustaining— GMP-exempt✓ Third-party review eligible
11
510(K)/PMA CLEARANCES
510k: 11
15
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is a candidate for a third party review program

SPEQ READINGAn Accredited Person may conduct the 510(k) review instead of FDA. FDA still makes the clearance decision — third-party review changes who reviews, never who decides.

Other product codes under 21 CFR 880.2910

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 880.2910 — Clinical electronic thermometer

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. A clinical electronic thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electronic signal amplification, conditioning, and display unit. The transducer may be in a detachable probe with or without a disposable cover.

(b) Classification. Class II (performance standards). The device is exempt from the premarket notification procedures in part 807, subpart E of this chapter, subject to the limitations in § 880.9 and the following conditions for exemption: (1) Device is not a clinical thermometer with telethermographic functions; (2) Device is not a clinical thermometer with continuous temperature measurement functions; and (3) Appropriate analysis and testing (such as that outlined in the currently FDA-recognized editions, as appropriate, of ISO 80601-2-56, “Medical electrical equipment—Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement,” or ASTM E1965, “Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature,” or ASTM E1112, “Standard Specification for Electronic Thermometer for Intermittent Determination of Patient Temperature,” or ASTM E1104, “Standard Specification for Clinical Thermometer Probe Covers and Sheaths”) must validate specifications and performance of the device. [45 FR 69682, Oct. 21, 1980, as amended at 90 FR 25891, June 18, 2025]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 880.2910 on eCFR →

Recent clearances

K253162Unimed Medical Supplies, Inc. · 510k2026-06-05
K251160Shenzhen Med-Link Electronics Tech Co., Ltd. · 510k2026-01-08
K250470Shenzhen AOJ Medical Technology Co., Ltd. · 510k2025-06-23
K243000Shenzhen Medke Technology Co., Ltd. · 510k2025-06-20
K250878Jiangsu Yuyue Medical Equipment & Supply Co., Ltd. · 510k2025-05-22
K243082Guangzhou Daxin Health Technology Co., Ltd. · 510k2025-04-25
K250401Aion Biosystems, Inc. · 510k2025-03-14
K243136Shenzhen Finicare Co., Ltd. · 510k2025-02-14

Recent recalls

Baxter Healthcare CorporationOpen, Classified · 2025-10-23

Affected oral/axillary probes were inadvertently programmed with the rectal probe configuration. Affected probes will potentially display a lower temperature than the true value, which may lead to a delay in managing fever-related symptoms or infection.

Philips Consumer LifestyleTerminated · 2018-02-22

Device may provide inaccurate measurements.

Bestmed, LLCTerminated · 2015-12-16

An incorrect calibration of the thermometer that causes the device to display inaccurate and frequently lower temperatures than the actual body temperature of the user.

Walgreen CompanyTerminated · 2012-01-11

The thermometers have been reported to have inaccurate readings

Smiths Medical ASD, Inc.Terminated · 2006-04-18

Product temperature readings may be 2C higher than the actual temperature

Smiths Medical ASD, Inc.Terminated · 2006-04-18

Product temperature readings may be 2C higher than the actual temperature

Omron Healthcare, Inc.Terminated · 2006-02-04

Omron is recalling the Omron 3-Way Instant Thermometers due to possible overheating of the probe tip.

Welch Allyn IncTerminated · 2004-01-16

Mechanical setting errors that result in calibration errors.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →