FDA PRODUCT CODE · CLASS II

NEW — Suture, Surgical, Absorbable, Polydioxanone

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 878.4840
MEDICAL SPECIALTY
General, Plastic Surgery
REVIEW PANEL
SU
✓ Implant— Life-sustaining— GMP-exempt— Third-party review eligible
12
510(K)/PMA CLEARANCES
510k: 12
7
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is not eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGIndividual malfunction reporting under 21 CFR Part 803 applies. The complaint-handling system has to produce a decision per event, not per period.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is implantable

SPEQ READINGImplant status raises the evidentiary bar on biocompatibility and on traceability from finished device back to material lot.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

21 CFR 878.4840 — Absorbable polydioxanone surgical suture

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. An absorbable polydioxanone surgical suture is an absorbable, flexible, sterile, monofilament thread prepared from polyester polymer poly (p-dioxanone) and is intended for use in soft tissue approximation, including pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. It may be coated or uncoated, undyed or dyed, and with or without a standard needle attached.

(b) Classification. Class II (special controls). The special control for the device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document. [67 FR 77676, Dec. 19, 2002]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 878.4840 on eCFR →

Recent clearances

K254238Hans Biomed Corporation · 510k2026-09-18
K253879Samyang Holdings Corporation · 510k2026-08-25
K261988Teleflex Medical, LLC · 510k2026-07-09
K252171Sutura Medical Technology, Inc. · 510k2026-06-12
K252047ETHICON, Inc. · 510k2026-05-18
K243897ETHICON, Inc. · 510k2025-11-12
K251414Feeltech Co., Ltd. · 510k2025-10-20
K250107Feeltech Co., Ltd. · 510k2025-10-15

Recent recalls

Ethicon, Inc.Open, Classified · 2022-12-14

knot tensile strengths were observed to be significantly below the minimum knot tensile, will result in breakage prior to use or intra-operatively rather than premature post-operative breakage

Ethicon, Inc.Terminated · 2019-10-04

The product does not meet certain internal strength testing specifications.

Ethicon, Inc.Terminated · 2019-10-04

The product does not meet certain internal strength testing specifications.

C P Medical, Inc.Terminated · 2014-10-27

CP Medical Inc. is recalling five lots of Monoswift PGCL [poly(glycolide-co-caprolactone)] Absorbable Surgical Suture for failing to meet the minimum tensile strength as dictated by USP was not met over the length of the product's shelf life.

Ethicon, Inc.Terminated · 2013-12-06

Ethicon Stratafix Symmetric PDS Plus Knotless Tissue Control Device has a small number of tab failures and fascial dehiscences in lower abdominal incisions.

Riverpoint Medical, LLCTerminated · 2013-11-18

Riverpoint Medical is recalling PGLA Surgical Suture (Vilet) because the label indicates the suture is undyed and it is actually a violet colored suture.

C P Medical Inc.Terminated · 2011-11-19

The seal integrity of the outer product pouch may be compromised due to partial delamination of the two layers that make up part of the pouch.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →