LWS — Implantable Cardioverter Defibrillator (Non-Crt)

These devices treat tachycardia (fast heartbeats) with RV defibrillation therapy as necessary.

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class III
MEDICAL SPECIALTY
Unknown
REVIEW PANEL
CV
✓ Implant✓ Life-sustaining— GMP-exempt— Third-party review eligible
14
510(K)/PMA CLEARANCES
pma: 14
76
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

PMA

SPEQ READINGPremarket approval under 21 CFR Part 814. FDA reviews safety and effectiveness directly rather than by comparison, so clinical evidence is normally expected and the quality system is inspected before approval rather than after marketing.

DEVICE CLASS

Class III (high risk): general controls and Premarket Approval (PMA)

SPEQ READINGGeneral controls are insufficient to assure safety and effectiveness, so approval rests on direct evidence rather than equivalence.

MALFUNCTION REPORTING

Device is not eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGIndividual malfunction reporting under 21 CFR Part 803 applies. The complaint-handling system has to produce a decision per event, not per period.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is implantable

SPEQ READINGImplant status raises the evidentiary bar on biocompatibility and on traceability from finished device back to material lot.

LIFE-SUSTAINING

Device is used for life sustaining purposes.

SPEQ READINGA life-sustaining designation is what brings device tracking under 21 CFR Part 821 into scope, and it raises what a risk file has to say about single-fault conditions.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

Recent clearances

P110042Boston Scientific Corporation · pma2026-10-02
P980023Biotronik, Inc. · pma2026-09-25
P980016Medtronic Cardiac Rhythm Disease Management · pma2026-09-25
P910073Boston Scientific · pma2026-09-17
P960040Boston Scientific · pma2026-08-25
P910023ABBOTT MEDICAL · pma2026-08-12
P220012Medtronic, Inc. · pma2026-07-31
P910077Boston Scientific · pma2026-07-01

Recent recalls

Medtronic, Inc.Open, Classified · 2025-11-28

There is a potential for delayed time to high-voltage (HV) therapy should a rare sequence of events occur.

Boston Scientific CorporationOpen, Classified · 2025-10-10

Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) a

Medtronic Inc.Open, Classified · 2024-01-22

During internal review of Polaris battery assembly data from the HiPot operation, a test systems engineer noticed that some batteries had gone through the High Potential test twice. This was able to occur because the test screen did not prevent retesting after a failure. Some batteries were therefor

Boston Scientific CorporationOpen, Classified · 2024-01-05

The software application on the Programmer/Recorder/Monitor (PRM) for Implantable Pulse Generators will display certain diagnostic dates incorrectly, with a year in the 1990s.

Boston Scientific CorporationTerminated · 2021-02-05

Electrical overstress may lead to device malfunction.

Boston Scientific CorporationTerminated · 2021-02-05

Electrical overstress may lead to device malfunction.

Boston Scientific CorporationTerminated · 2021-01-19

There is potential for fractures which results in the inability to delivery therapy.

Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF)Terminated · 2018-02-01

Possible prevention of high and low voltage therapy in Medtronic Implantable Cardioverter Defibrillators (ICDs) and Cardiac Resynchronization Therapy Defibrillator (CRT-D).

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →