FDA PRODUCT CODE · CLASS II

JAQ — System, Applicator, Radionuclide, Remote-Controlled

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 892.5700
MEDICAL SPECIALTY
Radiology
REVIEW PANEL
RA
— Implant— Life-sustaining— GMP-exempt— Third-party review eligible
12
510(K)/PMA CLEARANCES
510k: 12
26
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is not a candidate for a third party review program

SPEQ READINGFDA reviews any premarket notification for this code directly.

21 CFR 892.5700 — Remote controlled radionuclide applicator system

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. A remote controlled radionuclide applicator system is an electromechanical or pneumatic device intended to enable an operator to apply, by remote control, a radionuclide source into the body or to the surface of the body for radiation therapy. This generic type of device may include patient and equipment supports, component parts, treatment planning computer programs, and accessories.

(b) Classification. Class II.

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 892.5700 on eCFR →

Recent clearances

K262383Nucletron B.V. · 510k2026-07-24
K252717Varian Medical Systems · 510k2026-05-20
K251037Nucletron B.V. · 510k2025-12-19
K252884Varian Medical Systems · 510k2025-11-19
K250299Varian Medical Systems, Inc. · 510k2025-05-09
K250289Varian Medical Systems · 510k2025-04-25
K243939Varian Medical Systems, Inc. · 510k2025-03-03
K241764Varian Medical Systems, Inc. · 510k2025-01-10

Recent recalls

Varian Medical Systems, Inc.Terminated · 2013-10-24

The recall was initiated after Varian Medical became aware the Lexan templates of the Breast Bridge Template System could become bent and turn opaque after steam sterilization.

Varian Medical Systems, Inc.Terminated · 2013-01-31

A medical device used in brachytherapy may become contaminated and can cause infections, toxicity or allergic reactions.

Varian Medical Systems, Inc.Terminated · 2013-01-31

A medical device used in brachytherapy may become contaminated and can cause infections, toxicity or allergic reactions.

Varian Medical Systems, Inc.Terminated · 2012-12-20

The guide tube which is part of the Segmented Cervix Applicator Set is difficult to disconnect from cervical sleeve.

Varian Medical Systems, Inc.Terminated · 2011-12-01

Plastic needle tip could possibly crack or separate.

Varian Medical Systems, Inc.Terminated · 2011-12-01

Plastic needle tip could possibly crack or separate.

Varian Medical Systems, Inc. Oncology SystemsTerminated · 2011-12-01

The Product Models 1 & 2 have a design flaw problem where the clamping adapter can obstruct movement of the source cable in the event the bronchial catheter is dislodged from the connector.

Varian Medical Systems, Inc.Terminated · 2011-12-01

Plastic needle tip could possibly crack or separate.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →