FDA PRODUCT CODE · CLASS II

FOZ — Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 880.5200
MEDICAL SPECIALTY
General Hospital
REVIEW PANEL
HO
— Implant— Life-sustaining— GMP-exempt✓ Third-party review eligible
20
510(K)/PMA CLEARANCES
510k: 20
104
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is not eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGIndividual malfunction reporting under 21 CFR Part 803 applies. The complaint-handling system has to produce a decision per event, not per period.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is a candidate for a third party review program

SPEQ READINGAn Accredited Person may conduct the 510(k) review instead of FDA. FDA still makes the clearance decision — third-party review changes who reviews, never who decides.

Other product codes under 21 CFR 880.5200

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 880.5200 — Intravascular catheter

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials.

(b) Classification. Class II (performance standards).

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 880.5200 on eCFR →

Recent clearances

K260432Venocare, Inc. · 510k2026-09-02
K260165Spectrum Vascular · 510k2026-08-10
K261041MedSource Labs, LLC · 510k2026-07-10
K260539MedSource Labs, LLC · 510k2026-07-09
K253235B.Braun Medical, Inc. · 510k2026-05-15
K252137Becton Dickinson Infusion Therapy Systems, Inc. · 510k2026-04-02
K252513Poly Medicure Limited · 510k2026-04-01
K252398Terumo Medical Products (Hangzhou) Co., Ltd. · 510k2025-12-17

Recent recalls

Becton Dickinson Infusion Therapy Systems Inc.Open, Classified · 2023-11-24

Over-the-needle, intravascular catheters may have needles that do not retract properly into the barrel, which could result in contaminated needlestick injury, blood leaking from the insertion site or catheter, and repeat catheter insertion attempts, due to catheter being inadvertently removed from t

ARROW INTERNATIONAL Inc.Open, Classified · 2023-10-05

This recall has been initiated due to reports that the product code and product name were incorrectly listed on the lidstock of affected kits.

ARROW INTERNATIONAL Inc.Open, Classified · 2023-10-05

This recall has been initiated due to reports that the product code and product name were incorrectly listed on the lidstock of affected kits.

Becton Dickinson Infusion Therapy Systems Inc.Open, Classified · 2023-10-03

There is the potential that the safety shield may not properly engage on IV catheters. The needle can pull through the safety shield and disconnect from the needle safety shield leaving the contaminated needle point exposed.

ARROW INTERNATIONAL Inc.Terminated · 2022-12-10

There is the potential for inadequate connection between the top and bottom housings of the Micro Clave Clear Connectors included in the Arrow MAC Two-Lumen Central Venous Access Kit and the Arrow Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC Kit.

ARROW INTERNATIONAL Inc.Terminated · 2022-12-10

There is the potential for inadequate connection between the top and bottom housings of the Micro Clave Clear Connectors included in the Arrow MAC Two-Lumen Central Venous Access Kit and the Arrow Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC Kit.

Becton Dickinson Infusion Therapy Systems Inc.Open, Classified · 2022-11-03

During needle withdrawal, the tip shield may prematurely separate from the catheter adapter and preventing the needle tip from being in the safely shielded (leaving the needle tip exposed).

B Braun Medical IncOpen, Classified · 2022-10-06

Potential for leakage at the catheter hub.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →