FDA PRODUCT CODE · CLASS II

EMA — Cement, Dental

What these counts are not

Clearance and recall counts are SPEQ’s aggregation of FDA’s own published records for the code. A recall count is a measure of history, not of a device’s safety, neither number is an FDA rating, and SPEQ is not affiliated with the FDA.

DEVICE CLASS
Class II
REGULATION
21 CFR 872.3275
MEDICAL SPECIALTY
Dental
REVIEW PANEL
DE
— Implant— Life-sustaining— GMP-exempt✓ Third-party review eligible
17
510(K)/PMA CLEARANCES
510k: 17
6
RECALL ENTRIES

What this classification requires

Every statement below is FDA’s own classification record for this product code, quoted from the device classification field reference. The SPEQ reading beneath each one is SPEQ’s interpretation of what it means for the work, and is not FDA text.

PREMARKET PATHWAY

510(K)

SPEQ READINGA premarket notification under 21 CFR Part 807 Subpart E is the route for this code. The submission argues substantial equivalence to a legally marketed predicate, so the engineering question is which predicate the design can actually be compared against, and the evidence question is what testing supports that comparison.

DEVICE CLASS

Class II (moderate to high risk): general controls and special controls

SPEQ READINGSpecial controls are the distinguishing feature: performance standards, guidance documents, patient registries or postmarket surveillance named for the device type. Find the special controls before designing the test plan — they usually name the tests.

MALFUNCTION REPORTING

Device is eligible for The Voluntary Malfunction Summary Reporting Program

SPEQ READINGMalfunctions for this code may be reported in periodic summary form rather than as individual MDRs under 21 CFR Part 803. Eligibility is a property of the product code; using it is a decision the manufacturer makes and must be able to justify.

GMP / QUALITY SYSTEM

Not exempt due to Good Manufacturing Practice (GMP)/Quality System

SPEQ READINGThe full Quality Management System Regulation (21 CFR 820, incorporating ISO 13485:2016) applies, and is what an FDA inspection of this device will be conducted against.

IMPLANT

Device is not implantable

SPEQ READINGNo implant-specific expectations attach from the classification itself.

LIFE-SUSTAINING

Device is not used for life sustaining purposes

SPEQ READINGNo life-sustaining designation attaches to this code.

THIRD-PARTY REVIEW

Device is a candidate for a third party review program

SPEQ READINGAn Accredited Person may conduct the 510(k) review instead of FDA. FDA still makes the clearance decision — third-party review changes who reviews, never who decides.

Other product codes under 21 CFR 872.3275

One regulation usually governs several product codes. These share this code’s regulation, and therefore its classification basis.

21 CFR 872.3275 — Dental cement

The classification regulation for this product code, as published by the Office of the Federal Register. This is the regulation text itself — no SPEQ interpretation appears in it.

(a) Zinc oxide-eugenol —(1) Identification. Zinc oxide-eugenol is a device composed of zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp.

(2) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 872.9.

(b) Dental cement other than zinc oxide-eugenol —(1) Identification. Dental cement other than zinc oxide-eugenol is a device composed of various materials other than zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp.

(2) Classification. Class II. [52 FR 30097, Aug. 12, 1987, as amended at 65 FR 2314, Jan. 14, 2000]

Source: Electronic Code of Federal Regulations, Title 21. 21 CFR is a work of the United States Government and is in the public domain. SPEQ read this section on October 22, 2026. CFR is amended continuously, so verify against the source before acting on it: read 21 CFR 872.3275 on eCFR →

Recent clearances

K262983Spident Co., Ltd. · 510k2026-09-25
K254201Mediclus Co., Ltd. · 510k2026-08-13
K261937The Belport Company Inc., DBA Gingi-Pak · 510k2026-08-07
K261166DiaDent Group International · 510k2026-07-09
K254109GC America, Inc. · 510k2026-05-18
K253337Inter-Med, Inc. · 510k2026-04-15
K252606Voco GmbH · 510k2026-03-20
K254063Kulzer, LLC · 510k2025-12-19

Recent recalls

Family Dollar Stores, Llc.Open, Classified · 2023-11-07

Products were stored outside of labeled temperature requirements.

Henry Schein, Inc.Terminated · 2012-01-11

The specific lots of Maxcem Elite Refill Kit appear not to be authentic.

Kerr/pentron Dba Kerr Corporation And Pentron ClinicalTerminated · 2012-01-11

The firm initiated a recall because the product sets faster than specified in the "Directions for Use" and in release specifications.

Kerr CorporationTerminated · 2012-01-11

The resin material separates when the product is extruded from the syringe. Although there are no safety issues related with this situation, please refrain from using the affected product.

Kerr/pentron Dba Kerr Corporation And Pentron ClinicalTerminated · 2011-11-14

Pentron is voluntarily recalling the Breeze Self Adhesive Resin Cement because it was discovered that there may be a curing problem that may cause cemented crowns to fall off after use of the product.

Kerr CorpTerminated · 2009-10-23

The recall was initiated because the catalyst portion of the syringe may have polymerized, therefore making the product unusable.

Source: FDA device classification, 510(k)/PMA, and recall datasets. Recall entries count distinct FDA recall numbers, so one recall event affecting several products appears as several entries. Browse every product code SPEQ tracks →