FDA 483 OBSERVATION · #1649 OF 1,916 MOST-CITED
Measurements with tap water container
FDA cited this observation 6 times across 6 firms in recent inspections. Below: how it breaks down by program area and fiscal year, and real examples of how FDA worded it on Form FDA 483.
What this grouping is not
An observation-type page groups FDA’s published citation records. The grouping, the compliance steps and the root causes are SPEQ synthesis, not an FDA classification of any citation, and a count measures what FDA published rather than risk.
How FDA worded it — real examples
Microwave oven measurements were not made with the microwave oven containing a load of 275 ± 15 milliliters of tap water initially at 20 ± 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.
Microwave oven measurements were not made with the microwave oven containing a load of 275 ± 15 milliliters of tap water initially at 20 ± 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.
Microwave oven measurements were not made with the microwave oven containing a load of 275 ± 15 milliliters of tap water initially at 20 ± 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.
Microwave oven measurements were not made with the microwave oven containing a load of 275 ? 15 milliliters of tap water initially at 20 ? 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.
Microwave oven measurements were not made with the microwave oven containing a load of 275 ? 15 milliliters of tap water initially at 20 ? 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.
Microwave oven measurements were not made with the microwave oven containing a load of 275 ? 15 milliliters of tap water initially at 20 ? 5 degrees centigrade placed within the cavity at the center of the load-carrying surface provided by the manufacturer.